ClareOne June Update: 6/25/2021

The upcoming update introduces several minor ClareOne features and fixes.


ClareOne_v3

ClareOne

Auto updates:

This release sets all ClareOne panels to Auto Update by default. All existing panels are set to Auto Update once they receive the ClareOne 2.0.7/9.2.5 panel update.

Fan control:

The fan control settings are all now in blue. This makes the settings uniform and easily identifiable.

Corrected ClareOne booting message:

Removed the “Security is Disarmed..” panel annunciation after the panel boots. This prevents annoying/unexpected audio alerts when the panel updates or boots from a power loss.


Resolved Issues and Engineering Notes

Resolved Issues

Issue

Description/Resolution

CLO-3862

Symptom

Alarm zone names are not correctly reported to Control4.

Status

Zone names are properly reported to Control4.

CLO-3869

Symptom

With ethernet connection to a ClareOne device, rebooting the panel could cause the network layer to incorrectly initialize the Network Manager. This causes DNS initialization to fail.

Status

Ethernet connection to a ClareOne panel works correctly when rebooted.

CLO-3871

Symptom

The 360 PIR sensor only trips one time without being reset/tampered.

Status

The sensor now trips whenever there is motion detected and does not require a reset/tamper to accurately report.

CLO-3875

Symptom

When changing the zone profile for the ClareOne Door Window Sensor with External Contact, the takeover and normally open settings are changed.

Status

The takeover and normally open settings remain the same after a zone change.

CLO-3878

Symptom

There is only one available name for a 360 PIR sensor. This prevents a user from adding more than one to their account.

Status

Additional names have been added for the sensor.

CLO-3882

Symptom

The panic pendant is not displayed as a zone on the ClareOne panel. This causes an issue when the pendant gets into supervisory lost, causing the panel to announce supervisory lost when there is no apparent issue displayed on the panel.

Status

The panic pendant no longer reports supervisory lost.

CLO-3883 and 3887

Symptom

Zones set with a trigger profile display as ready on the ClareOne panel but not ready in the ClareHome app and Control4.

Status

Zones set with a trigger profile now display as ready on all attached panels and apps.

CLO-3887

Symptom

When changing the zone profile for the ClareOne Door Window Sensor with External Contact, the takeover and normally open settings are changed.

Status

The takeover and normally open settings remain as originally set.

AIT-636

Symptom

Faulting a motion sensor causes the AIT to chime even when the chime setting is set to off/disabled.

Status

The motion sensor only causes a chime from the AIT panel when set to chime and enabled.