Central Station Signal Test is a new feature added to ClareOne in the Fall 2021 release. It enables installers to send manual tests and to configure periodic test signals to the central station. A manual test will send a test signal code 601, and the periodic test will send a test signal code 602.
The central station test can be managed from FusionPro or directly on the ClareOne.
Manual test via FusionPro
- Open the account click on the devices tab.
- Click on the ClareOne device and wait for all sensor statuses to be returned.
- Click on Periodic Test Settings
- Click on Send a Test Message button to send a manual test signal, code 601, to the central station. Verify at the central station that the signal was received.
Scheduled test from FusionPro
- From the Periodic Test Settings option, select the interval to send the scheduled test. The options are Off, Daily, Weekly or Monthly.
- The selected interval is automatically saved to the ClareOne panel and a test signal, code 602, will be sent to the central station according to the interval setting.
- The Next Scheduled Test time stamp will update according to the interval set.
- The Last Scheduled Test time stamp will update each time a scheduled test is sent.
Manual test via ClareOne
- On the ClareOne panel, tap Settings > Installer Settings > Central Station Signal Test
- Click on Test button to send a manual test signal, code 601, to the central station. Verify at the central station that the signal was received.
Scheduled test from FusionPro
- From the Scheduled Auto Test pull down, select the interval to send the scheduled test. The options are Off, Daily, Weekly or Monthly.
- The selected interval is automatically saved and a test signal, code 602, will be sent to the central station according to the interval setting.
- The Next Scheduled Test time stamp will update according to the interval set.
- The Last Scheduled Test time stamp will update each time a scheduled test is sent.
Last Updated: 10/07/2021